30A/32A 8-Outlet 1U Outlet-Metered & Switched eco PDU
PG8308
Outlet-metered and switched eco PDU in 1U with 8 outlets and 30 A or 32 A input; per-outlet measurement and switching over 1 Gbps Ethernet, with JSON-RPC and Python scripting.
Features
- Supports 1Gbps Ethernet Interface
- Remote Management Protocols – TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP (TLS 1.2), ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet, Modbus (over TCP/IP), Wi-Fi, and IPv6
- Scripting – JSON-RPC (Remote Procedure Call) protocol and Python scripting to control specified PDU units
- Security – 2-level account/password login access, and IP/MAC filter, 128 bit SSL
- Authentication – RADIUS, LDAP, TACACS
- Supports eco DC and multiple browsers (IE, Firefox, Chrome, and Safari)
- Supports RS-232 and RS-485 communication ports
- Auto Ping & Reboot
- Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)
- Rotatable LCD Screen – capable of 180-degree rotation, delivering flexible in-rack installation
- Secure locking enhancement prevents power cords from becoming unplugged due to vibration or human error
- Metering and monitoring of power at the PDU and outlet levels
- Measuring and establishing threshold levels for current, voltage, power, power dissipation, temperature, and humidity
- Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
- Real-time alerts via LCD display notify users of unusual power states: – Home Screen Readings: A (aggregate Current), V (voltage), W (power), kWh (power consumption) – Types of Alerts: Critical, Alert (value exceeds a predefined threshold), Warning (value approaches alert threshold)
- Dual Ethernet ports support cascading up to 64 PDUs
- Daisy chaining functions support SNMP & Modbus protocols and TC / IP protocols (web page)
- Supports ATEN’s eco DC (Energy & DCIM Management Web GUI) for monitoring power distribution, energy, and environmental data from PDUs and connected devices
- Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
- Outlet group support at the PDU level
- Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
- Power-On/Off sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order
- Proactive overload protection (POP) – automatically powers off the last outlet, causing the current overload, while allowing users to set shutdown priority
- Schedule Control
- When the temperature or humidity sensor value reaches the predetermined threshold, the PDU can turn on, off, or reboot a particular outlet
- Energy-efficient relays allow operators to control large amounts of current flow for lower energy consumption
Electrical
- Nominal Input Voltage
- 100 – 120 VAC
- Nominal Input Voltage
- 100 – 240 VAC
- Nominal Input Voltage
- 100 – 240 VAC
- Maximum Input Current
- 30A Max ,24A(UL)
- Maximum Input Current
- 30A Max ,24A(UL)
- Maximum Input Current
- 32A Max
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Connection
- NEMA L5-30P
- Input Connection
- NEMA L6-30P
- Input Connection
- IEC 60309 32A
- Input Power
- 3600VA(Max),2880VA(UL)
- Input Power
- 7200VA(Max), 5760VA(UL)
- Input Power
- 7680VA(Max)
- Outlet Type
- (8) NEMA 5-20R
- Outlet Type
- (6) IEC320 C13+(2) IEC320 C19
- Outlet Type
- (6) IEC320 C13+(2) IEC320 C19
- Nominal Output Voltage
- 100 – 120 VAC
- Nominal Output Voltage
- 100 – 240 VAC
- Nominal Output Voltage
- 100 – 240 VAC
- Maximum Output Current (Outlet)
- 20A(Max), 16A(UL)
- Maximum Output Current (Outlet)
- C13:15A(Max),12A(UL) C19:20A(Max),16A(UL)
- Maximum Output Current (Outlet)
- C13:10A(Max) C19:16A(Max)
- Breakers
- UL489x2
- Breakers
- UL489x2
- Breakers
- UL489x2
- Metering
- Per Outlet level Current, Voltage , PF and KWh Monitoring
- Metering
- Per Outlet level Current, Voltage , PF and KWh Monitoring
- Metering
- Per Outlet level Current, Voltage , PF and KWh Monitoring
- Outlet Switching
- Yes
- Outlet Switching
- Yes
- Outlet Switching
- Yes
- Environment Sensor Ports
- 1xRJ45
- Environment Sensor Ports
- 1xRJ45
- Environment Sensor Ports
- 1xRJ45
- Metering Accuracy
- 1%
- Metering Accuracy
- 1%
- Metering Accuracy
- 1%
Physical Properties
- Dimensions (L x W x H)
- 43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
- Dimensions (L x W x H)
- 43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
- Dimensions (L x W x H)
- 43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
- Weight
- 4.65 kg ( 10.24 lb )
- Weight
- 4.65 kg ( 10.24 lb )
- Weight
- 4.65 kg ( 10.24 lb )
- Power Cord Length
- 3M(SR+NEMA L5-30P)
- Power Cord Length
- 3M(SR+NEMA L6-30P)
- Power Cord Length
- 3M(SR+IEC60309 32A)
Environmental
- Temperature (Operating / Storage)
- 0 – 60℃ / -20 – 60℃
- Temperature (Operating / Storage)
- 0 – 60℃ / -20 – 60℃
- Temperature (Operating / Storage)
- 0 – 60℃ / -20 – 60℃
- Humidity (Operating & Storage)
- 0 – 80% RH, Non-Condensing
- Humidity (Operating & Storage)
- 0 – 80% RH, Non-Condensing
- Humidity (Operating & Storage)
- 0 – 80% RH, Non-Condensing
Compliance
- EMC Verification
- FCC
- EMC Verification
- FCC
- EMC Verification
- CE
- Safety Verification
- UL,PSE
- Safety Verification
- UL,PSE
- Safety Verification
- CE,UKCA
- Note
- For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.
Firmware
Similar products

2X-EA07
Lok-U-Plug Cable Holder

2X-EA08
Lok-U-Plug Installation Tool

EA1140
Temperature Sensor

EA1240
Temperature & Humidity Sensor

EA1340
Differential Pressure & Temperature

EA1440
Photo Door Sensor

EA1441
Inductive Proximity Door Sensor

EA1442
Reed Door Sensor

EA1540
Capacitive Leakage Sensor

EA1640
Temperature & Humidity Sensor

ECO DC
Energy & DCIM Management Web GUI

ECO DC