Skip to content

Metered eco PDU in 1U with 8 outlets and 30 A or 32 A input; 1 Gbps Ethernet management with SNMP, JSON-RPC and Python scripting for automated power monitoring.

Features

  • Supports 1Gbps Ethernet Interface
  • Remote Management Protocols – TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP (TLS 1.2), ARP, NTP, DNS, SNMP V1, V2, and V3, Telnet, Modbus (over TCP/IP), Wi-Fi, and IPv6
  • Scripting – JSON-RPC (Remote Procedure Call) protocol and Python scripting to control specified PDU units
  • Security – 2-level account/password login access, and IP/MAC filter, 128 bit SSL
  • Authentication – RADIUS, LDAP, TACACS
  • Supports eco DC and multiple browsers (IE, Firefox, Chrome, and Safari)
  • Supports RS-232 and RS-485 communication ports.
  • Environment sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 ATEN EA1640 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats (sold separately)
  • Rotatable LCD Screen – capable of 180-degree rotation, delivering flexible in-rack installation
  • Secure locking enhancement prevents power cords from becoming unplugged due to vibration or human error
  • Metering and monitoring of power at the PDU and outlet levels
  • Measuring and establishing threshold levels for current, voltage, power, power dissipation, temperature, and humidity
  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking
  • Real-time alerts via LCD display notify users of unusual power states: – Home Screen Readings: A (aggregate Current), V (voltage), W (power), kWh (power consumption) – Types of Alerts: Critical, Alert (value exceeds a predefined threshold), Warning (value approaches alert threshold)
  • Dual Ethernet ports support cascading up to 64 PDUs
  • Daisy chaining functions support SNMP & Modbus protocols and TC / IP protocols (web page)
  • Supports ATEN’s eco DC (Energy & DCIM Management Web GUI) for monitoring power distribution, energy, and environmental data from PDUs and connected devices

Electrical

Nominal Input Voltage
100 – 120 VAC
Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
30A Max ,24A(UL)
Maximum Input Current
30A Max ,24A(UL)
Maximum Input Current
32A Max
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
NEMA L5-30P
Input Connection
NEMA L6-30P
Input Connection
IEC 60309 32A
Input Power
3600VA(Max),2880VA(UL)
Input Power
7200VA(Max),5760VA(UL)
Input Power
7680VA(Max)
Outlet Type
(8) NEMA 5-20R
Outlet Type
(6) IEC320 C13+(2) IEC320 C19
Outlet Type
(6) IEC320 C13+(2) IEC320 C19
Nominal Output Voltage
100 – 120 VAC
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
20A(Max), 16A(UL)
Maximum Output Current (Outlet)
C13:12A(UL) C19:16A(UL)
Maximum Output Current (Outlet)
C13:10A(Max) C19:16A(Max)
Breakers
UL489x2
Breakers
UL489x2
Breakers
UL489x2
Metering
Bank level Current, Voltage , PF and KWh Monitoring
Metering
Bank level Current, Voltage , PF and KWh Monitoring
Metering
Bank level Current, Voltage , PF and KWh Monitoring
Outlet Switching
No
Outlet Switching
No
Outlet Switching
No
Environment Sensor Ports
1xRJ45
Environment Sensor Ports
1xRJ45
Environment Sensor Ports
1xRJ45
USB 2.0 Type-A Port
Yes
USB 2.0 Type-A Port
Yes
USB 2.0 Type-A Port
Yes
Ethernet Port
10/100/1000M
Ethernet Port
10/100/1000M
Ethernet Port
10/100/1000M
PON + COM Port
1 x RJ-45
PON + COM Port
1 x RJ-45
PON + COM Port
1 x RJ-45
Metering Accuracy
1%
Metering Accuracy
1%
Metering Accuracy
1%

Physical Properties

Dimensions (L x W x H)
43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
Dimensions (L x W x H)
43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
Dimensions (L x W x H)
43.24 x 21.00 x 4.40 cm (17.02 x 8.27 x 1.73 in.)
Weight
4.27 kg ( 9.41 lb )
Weight
4.57 kg ( 10.08 lb )
Weight
3.99 kg ( 8.80 lb )
Power Cord Length
3M(SR+NEMA L5-30P)
Power Cord Length
3M(SR+NEMA L6-30P)
Power Cord Length
3M(SR+IEC60309 32A)

Environmental

Temperature (Operating / Storage)
0 – 60℃ / -20 – 60℃
Temperature (Operating / Storage)
0 – 60℃ / -20 – 60℃
Temperature (Operating / Storage)
0 – 60℃ / -20 – 60℃
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing

Compliance

EMC Verification
FCC
EMC Verification
FCC
EMC Verification
CE
Safety Verification
UL,PSE
Safety Verification
UL,PSE
Safety Verification
CE,UKCA
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.