As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage.

Features

  • Connections
  • Supports 10/100Mbit Ethernet, Modem, RS-232, Daisy Chain interface
  • Supports TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, STP, DCHP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2&V3, IPv6
  • Supports three-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS, TACACS+, LDAP, LDAPS and Active Directory
  • Supports CC2000, eco Sensors, Java API, multiple Browsers (IE, Firefox, Chrome, Safari), OOBC/RS232
  • Metering
  • PDU and outlet level power metering and monitoring
  • Environment monitoring – supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
  • Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
  • Outlet Switch Control
  • Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Outlet group support at the PDU and daisy chain level
  • Daisy chain with PON In – PON Out port
  • On/Off scheduling for individual outlets and outlet groups – power management tasks can be scheduled on a daily, weekly, monthly, or user-specified basis
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order
  • Critical load outlet – keeps power always on for critical load devices
  • Proactive overload protection – automatically powers off the last outlet that caused the current overload

Electrical

Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
20A Max; 16A(UL de-rated)
Maximum Input Current
16A Max
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
NEMA 6-20P
Input Connection
IEC 60320 C20
Input Power
4160 VA(Max); 3328 VA(UL de-rated)
Input Power
3680 VA(Max)
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 15A (Max); 12A(UL de-rated) C19: 20A (Max); 16A(UL de-rated)
Maximum Output Current (Outlet)
C13: 10A (Max) C19: 16A (Max); TUV De-rated 15A(Max)
Maximum Output Current (Bank)
20A(Max); 16A(UL de-rated)
Maximum Output Current (Bank)
16A(Max); TUV De-rated 15A(Max)
Maximum Output Current (Total)
20A(Max); 16A(UL de-rated)
Maximum Output Current (Total)
16A(Max); TUV De-rated 15A(Max)
Breakers
1 x 20A Non-Fuse breaker
Breakers
1 x 16A Non-Fuse breaker
Metering
Outlet Level Current, Voltage, VA, PF, KWh Monitoring
Metering
Outlet Level Current, Voltage, VA, PF, KWh Monitoring
Outlet Switching
Bank1-1: None Bank1-2: Yes
Outlet Switching
Bank1-1: None Bank1-2: Yes
Environment Sensor Ports
4
Environment Sensor Ports
4
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Physical Properties

Dimensions (L x W x H)
132.5 x 6.6 x 4.4 cm
Dimensions (L x W x H)
132.5 x 6.6 x 4.4 cm
Weight
3.8 kg
Weight
3.8 kg
Power Cord Length
1.6 m
Power Cord Length
1.6 m

Environmental

Temperature (Operating / Storage)
0 – 50°C / -20 – 60°C
Temperature (Operating / Storage)
0 – 40°C / -20 – 60°C
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing

Compliance

EMC Verification
FCC Part 15 Class A, Others by Request
EMC Verification
CE, C-Tick, Others by Request
Safety Verification
cTUVus, PSE, Others by Request
Safety Verification
TUV-CB, GOST, Others by Request
Note