Skip to content

20A/16A 16-Outlet Outlet-Metered & Switched eco PDU

PE8216

As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage.

Features

  • Supports 10 / 100M bit Ethernet interface
  • Supports TCP / IP, UDP, HTTP, HTTPS, SSL, DHCP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2 and V3
  • Supports three-level account / password security, IP / MAC filter, 128 bit SSL, and RADIUS
  • Supports CC2000, eco DC, multiple browsers (IE, Firefox, Chrome, and Safari)
  • PDU and outlet level power metering and monitoring
  • Environment monitoring – supports external temperature / temperature and humidity sensors for rack temperature and humidity monitoring
  • Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
  • Supports door sensor
  • Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Outlet group support at the PDU level
  • On / Off scheduling for individual outlet and outlet groups. Power management tasks can be scheduled on a daily, weekly, or user-specifi ed time basis
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order
  • Proactive overload protection (POP) – automatically powers off the last outlet that causes the current overload while allowing users to set shutdown priority
  • Supports SMTPS, IPv6, Modbus (Over TCP/IP), Auto Ping, TLS1.2, SSH
  • Supports IEEE 802.1X
  • Authentication: LDAP, TACACS+
  • UI – heartbeat,schedule control, mail control, and setting rule

Electrical

Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
20A Max; 16A(UL de-rated)
Maximum Input Current
16A Max
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
NEMA 6-20P
Input Connection
IEC 60320 C20
Input Power
4160 VA(Max); 3328 VA(UL de-rated)
Input Power
3680 VA(Max)
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Outlet Type
Total: 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 15A (Max); 12A(UL de-rated) C19: 20A (Max); 16A(UL de-rated)
Maximum Output Current (Outlet)
C13: 10A (Max) C19: 16A (Max)
Maximum Output Current (Bank)
20A(Max); 16A(UL de-rated)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
20A(Max); 16A(UL de-rated)
Maximum Output Current (Total)
16A(Max)
Breakers
1 x 20A Non-Fuse breaker
Breakers
1 x 16A Non-Fuse breaker
Metering
Outlet Level Current, Voltage, VA, PF, KWh Monitoring
Metering
Outlet Level Current, Voltage, VA, PF, KWh Monitoring
Outlet Switching
Yes
Outlet Switching
Yes
Environment Sensor Ports
4
Environment Sensor Ports
4
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Physical Properties

Dimensions (L x W x H)
132.48 x 6.60 x 4.40 cm (52.16 x 2.6 x 1.73 in.)
Dimensions (L x W x H)
132.48 x 6.60 x 4.40 cm (52.16 x 2.6 x 1.73 in.)
Weight
3.88 kg ( 8.55 lb )
Weight
3.88 kg ( 8.55 lb )
Power Cord Length
3 m
Power Cord Length
3 m

Environmental

Temperature (Operating / Storage)
0 – 50°C / -20 – 60°C
Temperature (Operating / Storage)
0 – 40°C / -20 – 60°C
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing
Humidity (Operating & Storage)
0 – 80% RH, Non-Condensing

Compliance

EMC Verification
FCC Part 15 Class A, Others by Request
EMC Verification
CE, Others by Request
Safety Verification
TUV-CB, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Firmware

Similar products