As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage.
Features
- Connections
- Support 10/100Mbit Ethernet Interface
- Support TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1,V2&V3
- Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIOUS
- Support : eco Sensors, Browser ( IE, Firefox, Chrome, Safari )
- Metering
- PDU and outlet level power metering and monitoring
- Environment monitoring — supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
- Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
- Support door sensor
- Outlet Switch Control
- Always On
Electrical
- Nominal Input Voltage
- 100 – 240 VAC
- Nominal Input Voltage
- 100 – 240 VAC
- Maximum Input Current
- 30A Max; 24A(UL de-rated)
- Maximum Input Current
- 32A Max
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Connection
- NEMA L6-30P
- Input Connection
- IEC 60309 32A
- Input Power
- 6240 VA(Max) 4992 VA (UL de-rated)
- Input Power
- 7360 VA(Max)
- Outlet Type
- Total: 24 x IEC320 C13 + 4 x IEC320 C19 Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19 Bank2: Outlet 15 – 28; 12 x C13 + 2 x C19
- Outlet Type
- Total: 24 x IEC320 C13 + 4 x IEC320 C19 Bank1: Outlet 1 – 14; 12 x C13 + 2 x C19 Bank2: Outlet 15 – 28; 12 x C13 + 2 x C19
- Nominal Output Voltage
- 100 – 240 VAC
- Nominal Output Voltage
- 100 – 240 VAC
- Maximum Output Current (Outlet)
- C13: 15A (Max); 12A(UL de-rated) C19: 15A (Max); 12A(UL de-rated)
- Maximum Output Current (Outlet)
- C13: 10A(Max) C19: 16A(Max); TUV De-rated 15A(Max)
- Maximum Output Current (Bank)
- 15A(Max); 12A(UL de-rated)
- Maximum Output Current (Bank)
- 16A(Max)
- Maximum Output Current (Total)
- 30A(Max); 24A(UL de-rated)
- Maximum Output Current (Total)
- 32A(Max)
- Breakers
- 2 x 16A UL489 Breaker
- Breakers
- 2 x 16A UL489 Breaker
- Metering
- Outlet Level Current, Voltage, VA, PF, KWh Monitoring
- Metering
- Outlet Level Current, Voltage, VA, PF, KWh Monitoring
- Outlet Switching
- None
- Outlet Switching
- None
- Environment Sensor Ports
- 4
- Environment Sensor Ports
- 4
- Metering Accuracy
- Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
- Metering Accuracy
- Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
- Dimensions (L x W x H)
- 135.98 x 6.60 x 4.40 cm (53.54 x 2.6 x 1.73 in.)
- Dimensions (L x W x H)
- 135.98 x 6.60 x 4.40 cm (53.54 x 2.6 x 1.73 in.)
- Weight
- 5.05 kg ( 11.12 lb )
- Weight
- 5.05 kg ( 11.12 lb )
- Power Cord Length
- 1.6 m
- Power Cord Length
- 1.6 m
Environmental
- Temperature (Operating / Storage)
- 0 – 50°C / -20 – 60°C
- Temperature (Operating / Storage)
- 0 – 40°C / -20 – 60°C
- Humidity (Operating & Storage)
- 0 – 80% RH, Non-Condensing
- Humidity (Operating & Storage)
- 0 – 80% RH, Non-Condensing
Compliance
- EMC Verification
- FCC Part 15 Class A, Others by Request
- EMC Verification
- CE, Others by Request
- Safety Verification
- By Request
- Safety Verification
- CE-LVD, Others by Request
- Note
- For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.
Firmware
Similar products

PE0316B
0U Basic PDU

PE0324B
0U Basic PDU

PE0116S
0U Basic PDU with Surge Protection

PE0216S
0U Basic PDU with Surge Protection

PE0224S
0U Basic PDU with Surge Protection

PE0316S
0U Basic PDU with Surge Protection

PE0324S
0U Basic PDU with Surge Protection

PE6108
15A/10A 8-Outlet 1U Metered & Switched eco PDU

PE5108
15A/10A 8-Outlet 1U Metered eco PDU

PE8108
15A/10A 8-Outlet 1U Outlet-Metered & Switched eco PDU

PE7108
15A/10A 8-Outlet 1U Outlet-Metered eco PDU

PE5221T