30A/32A 24-Outlet Metered & Switched eco PDU

PE6324

As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The

Features

  • Power Distribution
  • Space saving 0U rack mount design with rear mounting
  • IEC or NEMA outlet models
  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank
  • Remote users can monitor PDU/Bank status via web pages on their browsers
  • Safe shutdown support
  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker Remote Access
  • Remote power control via TCP/IP and a built in 10 / 100 Ethernet port
  • Network Protocols: TCP / IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping,Telnet
  • Energy & DCIM Management Web GUI – eco DC
  • Supports SNMP Manager V1, V2 & V3 Operation
  • Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
  • Easy setup and operation via a browser-based user interface
  • Multibrowser support (IE, Firefox, Chrome, Safari, Opera, and Netscape)
  • RTC support to keep the timer running during times of no power.
  • Up to 8 user accounts and 1 administrator account
  • Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices Management
  • Power status measurement at the PDU/Bank level
  • LED indicators for current and IP address at the PDU device and/or Bank levels
  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the bank level
  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring
  • Current and voltage threshold setting
  • Naming support for outlets
  • User outlet access assignment on an outlet-by-outlet basis
  • Event logging and syslog support
  • Upgradeable firmware
  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian Security
  • Two-level password security
  • Strong security features include strong password protection and advanced encryption technologies – 128 bit SSL
  • Remote authentication support: RADIUS eco DC Energy & DCIM Management Web GUI*
  • Automatic discovery of all PE devices within the same intranet
  • Remote real-time power measurement and monitoring
  • Remote real-time environment sensor monitoring
  • Plotting/Monitoring of all PE devices
  • Exceed threshold alert through SMTP and System log
  • Power Analysis Report *eco DC is designed to work with eco PDUs, and is bundled with all PE series packages.

Electrical

Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100 – 240 VAC
Maximum Input Current
30A(Max); 24A(UL de-rated)
Maximum Input Current
32A(Max)
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
NEMA L6-30P
Input Connection
IEC 60309 32A
Input Power
6240VA(Max); 4992VA(UL de-rated)
Input Power
7360VA(Max)
Outlet Type
Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Outlet Type
Total: 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19 Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19 Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100 – 240 VAC
Maximum Output Current (Outlet)
C13: 12A(Max) C19: 16A(Max)
Maximum Output Current (Outlet)
C13: 10A(Max) C19: 16A(Max)
Maximum Output Current (Bank)
15A(Max)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Total)
30A(Max)
Maximum Output Current (Total)
32A(Max)
Breakers
2 x 16A UL489 Breaker
Breakers
2 x 16A UL489 Breaker
Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Outlet Switching
Yes
Outlet Switching
Yes
Environment Sensor Ports
2
Environment Sensor Ports
2
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ Maximum Capacity +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Physical Properties

Dimensions (L x W x H)
177.50 x 6.60 x 4.40 cm (69.88 x 2.6 x 1.73 in.)
Dimensions (L x W x H)
177.50 x 6.60 x 4.40 cm (69.88 x 2.6 x 1.73 in.)
Weight
6.12 kg ( 13.48 lb )
Weight
6.12 kg ( 13.48 lb )
Power Cord Length
1.6 m
Power Cord Length
1.6 m

Environmental

Temperature (Operating / Storage)
0–50°C / -20–60°C
Temperature (Operating / Storage)
0–50°C / -20–60°C
Humidity (Operating & Storage)
0–80% RH, Non-Condensing
Humidity (Operating & Storage)
0–80% RH, Non-Condensing

Compliance

EMC Verification
FCC, Others by Request
EMC Verification
CE, C-Tick, Others by Request
Safety Verification
cTUVus, PSE, Others by Request
Safety Verification
TUV-CB, CE-LVD, Others by Request
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.