Skip to content

Network-managed eco PDU with 8 outlets and up to 20 A input; 10/100 Mbit Ethernet with SNMP management, and a detachable front panel fitting 19-inch racks of different depths.

Features

  • Connections
  • Detachable front panel fits 19” racks with different depths
  • Built-in 10/100 Mbit Ethernet Interface
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
  • 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
  • Browser access via IE, Firefox, Chrome, Safari, and more
  • Easy integration with ATEN Control System and Control4 libraries
  • Supports RS-232 port and power outlet control (on/off) by outlet group
  • Metering
  • 1% Metering Accuracy – supports bank-level power metering
  • Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring
  • Outlet Switch Control
  • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety
  • Proactive Overload Protection (POP) – automatically powers off the last outlet that caused the current overload to protect high-end ProAV equipment and servers
  • eco DC Energy Management Software*
  • Automatic discovery of all ATEN PDUs within the same intranet
  • Remote real-time power measurement and monitoring of PDUs
  • Real-time environment monitoring via sensors
  • Plotting and monitoring of all ATEN PDU devices
  • Exceed threshold alerts through real-time monitoring, SMTP, and System logs
  • Power analysis reports * eco DC is designed to work with NRGence™ eco PDUs and is bundled with all PE Series models.
  • Features available only on firmware-upgraded models with -ATB part number
  • Supports SMTPS, IPv6, Modbus (Over TCP/IP), Auto Ping, TLS1.2, SSH
  • Supports IEEE 802.1X
  • Authentication: LDAP, TACACS+
  • UI – heartbeat,schedule control, mail control, and setting rule

Electrical

Nominal Input Voltage
100 – 120 VAC
Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100 – 240 VAC
Nominal Input Voltage
100-240 VAC
Maximum Input Current
20A(Max), 16A(UL de-rated)
Maximum Input Current
20A(Max)16A(UL de-rated)
Maximum Input Current
16A(Max)
Maximum Input Current
16A(Max)
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
A/J:NEMA L5-20P A2/J2: NEMA 5-20P
Input Connection
NEMA 6-20P
Input Connection
IEC 60320 C20
Input Connection
Terminal(3P)
Input Power
2400VA(Max),1920VA(UL de-rated)
Input Power
4600VA(Max),3680VA(UL de-rated)
Input Power
3680 VA(Max)
Input Power
4800VA(Max)
Outlet Type
Total : 8 x NEMA 5-20R
Outlet Type
Total: 8 x IEC320 C13
Outlet Type
Total: 8 x IEC320 C13
Outlet Type
Total : 8 x Terminal(3P)
Nominal Output Voltage
100 –120 VAC
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100 – 240 VAC
Nominal Output Voltage
100-240 VAC
Maximum Output Current (Outlet)
NEMA 5-20R : 20A (Max) 16A (UL de-rated)
Maximum Output Current (Outlet)
C13: 15A(Max) 12A(UL de-rated)
Maximum Output Current (Outlet)
C13: 10A
Maximum Output Current (Outlet)
16A (Max)
Maximum Output Current (Bank)
20A (Max) 16A (UL de-rated)
Maximum Output Current (Bank)
20A (Max) 16A (UL de-rated)
Maximum Output Current (Bank)
16A(Max)
Maximum Output Current (Bank)
16A (Max)
Maximum Output Current (Total)
20A (Max) 16A (UL de-rated)
Maximum Output Current (Total)
20A (Max) 16A (UL de-rated)
Maximum Output Current (Total)
16A(Max)
Maximum Output Current (Total)
16A (Max)
Metering
Per Bank level Current, Voltage, VA , PF and KWh Monitoring
Metering
Per Bank level Current, Voltage, VA , PF and KWh Monitoring
Metering
Bank Level Current, Voltage, VA , PF and kWh Monitoring
Metering
Per Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet Switching
Yes
Outlet Switching
Yes
Outlet Switching
Yes
Outlet Switching
Yes
Environment Sensor Ports
2
Environment Sensor Ports
2
Environment Sensor Ports
2
Environment Sensor Ports
2
Metering Accuracy
Voltage range: 100VAC ~ 250VAC +/-1% Power range: 100W ~ 5000W +/- 2% Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
Voltage range: 100VAC ~ 250VAC +/-1% Power range: 100W ~ 5000W +/- 2% Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Metering Accuracy
"Voltage range: 100VAC ~ 250VAC +/-1% Power range: 100W ~ 5000W +/- 2% Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%"
Metering Accuracy
Voltage range: 100VAC ~ 250VAC +/-1% Power range: 100W ~ 5000W +/- 2% Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Communication

10/100 Mbps
1 x RJ-45
10/100 Mbps
1 x RJ-45
10/100 Mbps
1 x RJ-45
10/100 Mbps
1 x RJ-45
RS-232
1 x DB-9
RS-232
1 x DB-9
RS-232
1 x DB-9
RS-232
1 x DB-9

Switches

Power
Yes
Power
Yes
Power
Yes
Power
Yes

Physical Properties

Dimensions (L x W x H)
43.24 x 26.72 x 4.4 cm (17.02 x 10.52 x 1.73 in.)
Dimensions (L x W x H)
43.24 x 26.72 x 4.4 cm (17.02 x 10.52 x 1.73 in.)
Dimensions (L x W x H)
43.24 x 26.72 x 4.4 cm (17.02 x 10.52 x 1.73 in.)
Dimensions (L x W x H)
43.24 x 26.72 x 4.4 cm (17.02 x 10.52 x 1.73 in.)
Weight
3.76 kg (8.29 lb)
Weight
3.76 kg (8.29 lb)
Weight
3.76 kg (8.29 lb)
Weight
3.76 kg (8.29 lb)
Power Cord Length
3 m
Power Cord Length
3 m
Power Cord Length
3 m
Power Cord Length
N.A.

Environmental

Temperature (Operating / Storage)
0 – 50℃ / -20 – 60℃
Temperature (Operating / Storage)
0 – 50℃ / -20 – 60℃
Temperature (Operating / Storage)
0–40°C / -20–60°C
Temperature (Operating / Storage)
0 – 50℃ / -20 – 60℃
Humidity (Operating & Storage)
0–80% RH, Non-Condensing
Humidity (Operating & Storage)
0–80% RH, Non-Condensing
Humidity (Operating & Storage)
0–80% RH, Non-Condensing
Humidity (Operating & Storage)
0–80% RH, Non-Condensing

Compliance

EMC Verification
FCC, J55032
EMC Verification
FCC Others by Request
EMC Verification
CE-EMC, FCC, J55032 Others by Request
EMC Verification
FCC,CE
Safety Verification
PSE
Safety Verification
Others by Request
Safety Verification
CE-LVD, PSE, Others by Request
Safety Verification
CE,LVD
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Firmware