Network-managed eco PDU with 8 NEMA 5-15R outlets on a 15 A, 1800 VA input; 10/100 Mbit Ethernet with SNMP, and a detachable front panel that fits 19-inch racks of different depths.

Features

  • Detachable front panel fits 19” racks with different depths
  • Built-in 10/100 Mbit Ethernet Interface
  • Supports TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1, V2, and V3, Telnet
  • 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS
  • Browser access via IE, Firefox, Chrome, Safari, and more
  • Easy integration with ATEN Control System and Control4 libraries
  • Supports RS-232 port and power outlet control (on/off) by outlet group.
  • 1% Metering Accuracy – supports bank-level power metering
  • Environment Monitoring – supports external temperature or temperature and humidity sensors for rack temperature and humidity monitoring
  • Remote and local power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
  • Multiple Power Control Methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-On Sequencing – users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the correct order to enhance equipment safety
  • Proactive Overload Protection (POP) : - automatically powers off outlets when current overloads to protect operating devices. - Priority Mode enables outlets to be powered off following the outlet shutdown order pre-defiend by the administrator via web browser
  • Auto Ping – the method pings a device at specified intervals, and if there is no response (request timed out), the PDU automatically powers cycles the outlet (off and then on)
  • Holiday Mode – when Holiday Mode is enabled, each outlet will be set to the selection chosen for it: POWER OFF or POWER ON
  • Automatic discovery of all ATEN PDUs within the same intranet
  • Remote real-time power measurement and monitoring of PDUs
  • Real-time environment monitoring via sensors
  • Plotting and monitoring of all ATEN PDU devices
  • Exceed threshold alerts through real-time monitoring, SMTP, and System logs
  • Power analysis reports * eco DC is designed to work with ATEN eco PDUs and is bundled with all PE Series models.
  • Supports SMTPS, IPv6, Modbus (Over TCP/IP), Auto Ping, TLS1.2, SSH
  • Supports IEEE 802.1X
  • Authentication: LDAP, TACACS+
  • UI – heartbeat,schedule control, mail control, and setting rule

Electrical

Nominal Input Voltage
100 – 120 VAC
Maximum Input Current
15A(Max), 12A(UL de-rated)
Input Frequency
50-60 Hz
Input Connection
For A/J Plug:NEMA 5-15P
Input Power
1800VA(Max),1440VA(UL de-rated)
Outlet Type
Total : 8 x NEMA 5-15R
Nominal Output Voltage
100-120 VAC
Maximum Output Current (Outlet)
NEMA 5-15R : 15A (Max) 12A (UL de-rated)
Maximum Output Current (Bank)
15A (Max) 12A (UL de-rated)
Maximum Output Current (Total)
15A (Max) 12A (UL de-rated)
Metering
Per Bank level Current, Voltage, VA , PF and KWh Monitoring
Outlet Switching
Yes
Environment Sensor Ports
2
Metering Accuracy
Voltage range: 100VAC ~ 250VAC +/-1% Power range: 100W ~ 5000W +/- 2% Current range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

Communication

10/100 Mbps
1 x RJ-45
RS-232
1 x DB-9

Switches

Power
Yes

Environmental

Temperature (Operating / Storage)
0 – 45℃ / -20 – 60℃
Humidity (Operating & Storage)
0–80% RH, Non-Condensing

Physical Properties

Dimensions (L x W x H)
43.24 x 26.73 x 4.40 cm (17.02 x 10.52 x 1.73 in.)
Weight
3.70 kg ( 8.15 lb )
Power Cord Length
3 m

Compliance

EMC Verification
FCC, J55022
Safety Verification
PSE
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Firmware