The PE2340 Energy PDU contains 40 AC outlets and is available in IEC or NEMA socket configurations. The PE2340 Energy PDU features a space-saving 0U design that allows it to
Features
- Space saving 0U rack mount design
- IEC or NEMA outlet models
- Real-time PDU current monitoring * * When used in conjunction with the EC2004 Energy Box
Electrical
- Nominal Input Voltage
- 100 – 240 VAC
- Nominal Input Voltage
- 100 – 240 VAC
- Maximum Input Current
- 30A(Max)
- Maximum Input Current
- 32A(Max)
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Connection
- NEMA L6-30P
- Input Connection
- IEC 60309 32A
- Input Power
- 6240 VA(Max)
- Input Power
- 7360 VA(Max)
- Outlet Type
- Total: 40 x IEC320 C13 Bank1: Outlet 1 – 20; 20 x C13 Bank2: Outlet 21 – 40; 20 x C13
- Outlet Type
- Total: 40 x IEC320 C13 Bank1: Outlet 1 – 20; 20 x C13 Bank2: Outlet 21 – 40; 20 x C13
- Nominal Output Voltage
- 100 – 240 VAC
- Nominal Output Voltage
- 100 – 240 VAC
- Maximum Output Current (Outlet)
- 15A(Max)
- Maximum Output Current (Outlet)
- 10A(Max)
- Maximum Output Current (Bank)
- 15A(Max)
- Maximum Output Current (Bank)
- 16A(Max)
- Maximum Output Current (Total)
- 30A(Max)
- Maximum Output Current (Total)
- 32A(Max)
- Breakers
- 2 x 16A UL489 Breaker
- Breakers
- 2 x 16A UL489 Breaker
- Metering
- Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box)
- Metering
- Bank Level Current/Voltage Monitoring (Via EC2004 Energy Box)
- Outlet Switching
- None
- Outlet Switching
- None
- Environment Sensor Ports
- 0
- Environment Sensor Ports
- 0
- Metering Accuracy
- Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
- Metering Accuracy
- Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
Physical Properties
- Dimensions (L x W x H)
- 132.5 x 6.6 x 4.4 cm
- Dimensions (L x W x H)
- 132.5 x 6.6 x 4.4 cm
- Weight
- 4.65 kg
- Weight
- 4.65 kg
- Power Cord Length
- 1.6 m
- Power Cord Length
- 1.6 m
Environmental
- Temperature (Operating / Storage)
- 0–50°C / -20–60°C
- Temperature (Operating / Storage)
- 0–40°C / -20–60°C
- Humidity (Operating & Storage)
- 0–80% RH, Non-Condensing
- Humidity (Operating & Storage)
- 0–80% RH, Non-Condensing
Compliance
- EMC Verification
- FCC, Others by Request
- EMC Verification
- CE, Others by Request
- Safety Verification
- By Request
- Safety Verification
- CE-LVD, Others by Request
- Note
- For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.
Similar products

PE0316B
0U Basic PDU

PE0324B
0U Basic PDU

PE0116S
0U Basic PDU with Surge Protection

PE0216S
0U Basic PDU with Surge Protection

PE0224S
0U Basic PDU with Surge Protection

PE0316S
0U Basic PDU with Surge Protection

PE0324S
0U Basic PDU with Surge Protection

PE6108
15A/10A 8-Outlet 1U Metered & Switched eco PDU

PE5108
15A/10A 8-Outlet 1U Metered eco PDU

PE8108
15A/10A 8-Outlet 1U Outlet-Metered & Switched eco PDU

PE7108
15A/10A 8-Outlet 1U Outlet-Metered eco PDU

PE5221T