0U Basic PDU with Surge Protection

PE0216S

Basic 0U rack PDU with surge protection, mounting vertically so no rack units are used; aluminum build, IEC or NEMA outlets, maximum input 20 A.

Features

  • Space saving – 0U rack mount design
  • IEC or NEMA outlet models
  • Surge protection
  • Aluminum material
  • Works with data centers, server rooms, and telecom equipment

Electrical

Nominal Input Voltage
100-120 VAC
Nominal Input Voltage
100-240 VAC
Nominal Input Voltage
100-240 VAC
Maximum Input Current
20A Max (UL de-dated 16A Max)
Maximum Input Current
20A Max (UL de-rated 16A Max)
Maximum Input Current
16A Max
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
For A Plug: NEMA L5-20P For A2 Plug: NEMA 5-20P
Input Connection
NEMA L6-20P
Input Connection
IEC-320 C20
Input Power
2400VA(Max); 1920VA(UL de-rated)
Input Power
4800VA(Max); 3840VA(UL de-rated)
Input Power
3840VA(Max)
Outlet Type
(16) NEMA 5-20R
Outlet Type
(16) IEC 320 C13
Outlet Type
(16) IEC 320 C13
Maximum Output Current (Outlet)
20 Max (UL de-dated 16A Max)
Maximum Output Current (Outlet)
15A Max (UL de-rated 12A Max)
Maximum Output Current (Outlet)
10A Max
Maximum Output Current (Bank)
20 Max (UL de-dated 16A Max)
Maximum Output Current (Bank)
20A Max (UL de-rated 16A Max)
Maximum Output Current (Bank)
16A Max
Maximum Output Current (Total)
20A Max (UL de-dated 16A Max)
Maximum Output Current (Total)
20A Max (UL de-rated 16A Max)
Maximum Output Current (Total)
16A Max
OPD(Overcurrent Protection Device)
Yes
OPD(Overcurrent Protection Device)
Yes
OPD(Overcurrent Protection Device)
Yes

Physical Properties

Dimensions (L x W x H)
71.56 x 4.44 x 6.00 cm (28.17 x 1.75 x 2.36 in.)
Dimensions (L x W x H)
71.56 x 4.44 x 6.00 cm (28.17 x 1.75 x 2.36 in.)
Dimensions (L x W x H)
71.56 x 4.44 x 6.00 cm (28.17 x 1.75 x 2.36 in.)
Weight
1.10 kg ( 2.42 lb )
Weight
1.10 kg ( 2.42 lb )
Weight
1.10 kg ( 2.42 lb )
Power Cord Length
10ft(12#)
Power Cord Length
10ft(12#)
Power Cord Length
10ft(3×1.5mm2)

Environmental

Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃
Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃
Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃
Elevation (Operating / Storage)
3000m
Elevation (Operating / Storage)
3000m
Elevation (Operating / Storage)
3000m

Compliance

EMC Verification
FCC Class A
EMC Verification
FCC Class A
EMC Verification
CE Class A
Safety Verification
UL, other by request
Safety Verification
UL, other by request
Safety Verification
CE,LVD, UL
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.