Skip to content

Basic rack PDU in a 1U aluminum housing for server power distribution; IEC or NEMA outlet models with maximum input of 20 A.

Features

  • Space saving -1U rack mount design
  • IEC or NEMA outlet models
  • Aluminum material
  • Servers
  • Network Devices
  • Telecom Equipment

Electrical

Nominal Input Voltage
100-120 VAC
Nominal Input Voltage
100-240 VAC
Nominal Input Voltage
100-240 VAC
Maximum Input Current
20A Max (UL de-rated 16A Max)
Maximum Input Current
20A (Max) (UL de-rated 16A Max)
Maximum Input Current
16A (Max)
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Frequency
50-60 Hz
Input Connection
For A Plug NEMA L5-20P For A2 Plug : NEMA 5-20P
Input Connection
NEMA L6-20P
Input Connection
IEC-320 C20
Input Power
2400VA(MAX); 1920VA(UL de-rated)
Input Power
4800VA(Max); 3840VA(UL de-rated)
Input Power
3840VA(Max)
Outlet Type
(12) NEMA 5-20R
Outlet Type
(12) IEC 320 C13
Outlet Type
(12) IEC 320 C13
Maximum Output Current (Outlet)
20A (Max) (UL de-rated 16A Max)
Maximum Output Current (Outlet)
15A (Max) (UL de-rated 12A Max)
Maximum Output Current (Outlet)
10A (Max)
Maximum Output Current (Bank)
20A (Max) (UL de-rated 16A Max)
Maximum Output Current (Bank)
20A (Max) (UL de-rated 16A Max)
Maximum Output Current (Bank)
16A (Max)
Maximum Output Current (Total)
20A (Max) (UL de-rated 16A Max)
Maximum Output Current (Total)
20A (Max) (UL de-rated 16A Max)
Maximum Output Current (Total)
16A (Max)
OPD(Overcurrent Protection Device)
Yes
OPD(Overcurrent Protection Device)
Yes
OPD(Overcurrent Protection Device)
Yes

Physical Properties

Dimensions (L x W x H)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
Dimensions (L x W x H)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
Dimensions (L x W x H)
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
Weight
0.63 kg ( 1.39 lb )
Weight
0.63 kg ( 1.39 lb )
Weight
0.63 kg ( 1.39 lb )
Power Cord Length
10ft(12#)
Power Cord Length
10ft(12#)
Power Cord Length
10ft(3×1.5mm2)

Environmental

Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
Temperature (Operating / Storage)
0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
Elevation (Operating / Storage)
3000m
Elevation (Operating / Storage)
3000m
Elevation (Operating / Storage)
3000m

Compliance

EMC Verification
FCC Class A
EMC Verification
FCC Class A
EMC Verification
-
Safety Verification
UL, other by request
Safety Verification
UL, other by request
Safety Verification
LVD, UL
Note
For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

Similar products