Basic rack PDU in a 1U aluminum housing for server power distribution; IEC or NEMA outlet models with maximum input of 20 A.
Features
- Space saving -1U rack mount design
- IEC or NEMA outlet models
- Aluminum material
- Servers
- Network Devices
- Telecom Equipment
Electrical
- Nominal Input Voltage
- 100-120 VAC
- Nominal Input Voltage
- 100-240 VAC
- Nominal Input Voltage
- 100-240 VAC
- Maximum Input Current
- 20A Max (UL de-rated 16A Max)
- Maximum Input Current
- 20A (Max) (UL de-rated 16A Max)
- Maximum Input Current
- 16A (Max)
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Connection
- For A Plug NEMA L5-20P For A2 Plug : NEMA 5-20P
- Input Connection
- NEMA L6-20P
- Input Connection
- IEC-320 C20
- Input Power
- 2400VA(MAX); 1920VA(UL de-rated)
- Input Power
- 4800VA(Max); 3840VA(UL de-rated)
- Input Power
- 3840VA(Max)
- Outlet Type
- (12) NEMA 5-20R
- Outlet Type
- (12) IEC 320 C13
- Outlet Type
- (12) IEC 320 C13
- Maximum Output Current (Outlet)
- 20A (Max) (UL de-rated 16A Max)
- Maximum Output Current (Outlet)
- 15A (Max) (UL de-rated 12A Max)
- Maximum Output Current (Outlet)
- 10A (Max)
- Maximum Output Current (Bank)
- 20A (Max) (UL de-rated 16A Max)
- Maximum Output Current (Bank)
- 20A (Max) (UL de-rated 16A Max)
- Maximum Output Current (Bank)
- 16A (Max)
- Maximum Output Current (Total)
- 20A (Max) (UL de-rated 16A Max)
- Maximum Output Current (Total)
- 20A (Max) (UL de-rated 16A Max)
- Maximum Output Current (Total)
- 16A (Max)
- OPD(Overcurrent Protection Device)
- Yes
- OPD(Overcurrent Protection Device)
- Yes
- OPD(Overcurrent Protection Device)
- Yes
Physical Properties
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Weight
- 0.63 kg ( 1.39 lb )
- Weight
- 0.63 kg ( 1.39 lb )
- Weight
- 0.63 kg ( 1.39 lb )
- Power Cord Length
- 10ft(12#)
- Power Cord Length
- 10ft(12#)
- Power Cord Length
- 10ft(3×1.5mm2)
Environmental
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Elevation (Operating / Storage)
- 3000m
- Elevation (Operating / Storage)
- 3000m
- Elevation (Operating / Storage)
- 3000m
Compliance
- EMC Verification
- FCC Class A
- EMC Verification
- FCC Class A
- EMC Verification
- -
- Safety Verification
- UL, other by request
- Safety Verification
- UL, other by request
- Safety Verification
- LVD, UL
- Note
- For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.
Similar products

RC1000
15U Standard Rack with Perforated Front and Rear Doors

RC1100
20U Standard Rack with Perforated Front and Rear Doors

RC1200
25U Standard Rack with Perforated Front and Rear Doors

RC1300
30U Standard Rack with Perforated Front and Rear Doors

RC1400
35U Standard Rack with Perforated Front and Rear Doors

RC1500
42U Standard Rack with Perforated Front and Rear Doors

RC1600
42U Server Rack with Perforated Front and Rear Doors

RC1700
42U Server Rack with Perforated Front Door and Split Rear Door

RC1800
42U Network/Server Rack with Perforated Front and Rear Doors

RC1900
6U/8U Wall Mount Rack

RC2000
10U/12U/15U Wall Mount Rack

RC2100