Basic 1U rack PDU with surge protection for 20 A maximum input; aluminum housing available in IEC or NEMA outlet configurations.
Features
- Space saving -1U rack mount design
- IEC or NEMA outlet models
- Surge Protection
- Aluminum material
- Works with data centers, server rooms and telecom equipment
Electrical
- Nominal Input Voltage
- 100-120 VAC
- Nominal Input Voltage
- 100-240 VAC
- Nominal Input Voltage
- 100-240 VAC
- Maximum Input Current
- 20A Max (UL de-rated 16A Max)
- Maximum Input Current
- 20A Max (UL de-rated 16A Max)
- Maximum Input Current
- 16A (Max)
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Frequency
- 50-60 Hz
- Input Connection
- For A Plug: NEMA L5-20P For A2 Plug:NEMA 5-20P
- Input Connection
- NEMA L6-20P
- Input Connection
- For G Plug: IEC-320 C20 For Z Plug: Chinese 16A
- Input Power
- 2400VA(Max); 1920VA(UL de-rated)
- Input Power
- 4800VA(Max); 3840VA(UL de-rated)
- Input Power
- 3840VA(Max)
- Outlet Type
- (10) NEMA 5-20R
- Outlet Type
- (10) IEC 320 C13
- Outlet Type
- (10) IEC 320 C13
- Maximum Output Current (Outlet)
- 20A Max (UL de-rated 16A Max)
- Maximum Output Current (Outlet)
- 15A Max (UL de-rated 12A Max)
- Maximum Output Current (Outlet)
- 10A (Max)
- Maximum Output Current (Bank)
- 20A Max (UL de-rated 16A Max)
- Maximum Output Current (Bank)
- 20A Max (UL de-rated 16A Max)
- Maximum Output Current (Bank)
- 16A (Max)
- Maximum Output Current (Total)
- 20A Max (UL de-rated 16A Max)
- Maximum Output Current (Total)
- 20A Max (UL de-rated 16A Max)
- Maximum Output Current (Total)
- 16A (Max)
- OPD(Overcurrent Protection Device)
- Yes
- OPD(Overcurrent Protection Device)
- Yes
- OPD(Overcurrent Protection Device)
- Yes
Physical Properties
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Dimensions (L x W x H)
- 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.)
- Weight
- 0.67 kg ( 1.48 lb )
- Weight
- 0.67 kg ( 1.48 lb )
- Weight
- 0.67 kg ( 1.48 lb )
- Power Cord Length
- 10ft(12#)
- Power Cord Length
- 10ft(12#)
- Power Cord Length
- 10ft(3*2.5mm2)
Environmental
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Temperature (Operating / Storage)
- 0 – 40℃ / -20 – 60℃ *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
- Elevation (Operating / Storage)
- 3000m
- Elevation (Operating / Storage)
- 3000m
- Elevation (Operating / Storage)
- 3000m
Compliance
- EMC Verification
- FCC Class A
- EMC Verification
- FCC Class A
- EMC Verification
- -
- Safety Verification
- UL
- Safety Verification
- UL
- Safety Verification
- LVD
- Note
- For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.